BRAND | Wilo |
Product | 2189123 |
Description | Dry rotor block pump WITH frequency converter |
Internal code | IMP4718836 |
Technical specification | Stratos GIGA B 80/1-13/1.9 High-efficiency block pump with EC motor of the Efficiency class IE5 in accordance with IEC 60034-30-2 and electronic Power adjustment in dry runner design. The pump is designed as a single-stage low-pressure centrifugal pump with flange connection and mechanical seal. The Stratos GIGA B is primarily for pumping heating water (in accordance with VDI 2035), Cold water and water-glycol mixtures without abrasive substances in heating, air conditioning and cooling systems designed. Construction: - Single-stage low-pressure centrifugal pump with undivided shaft in Block design including foot on pump housing - Flange and housing dimensions according to EN 733 - PN 16 flanges - drilled according to EN 1092-2 - Pressure measurement connections (R 1/8) for attached Differential pressure transmitter (version... -R1 without differential pressure sensor) - pump housing and motor flange as standard with cataphoresis coating - Mechanical seal for water delivery up to Tmax. = +140°C. Up to T = +40°C, a glycol admixture of 20% to 40% is Volume percentage allowed. In the case of water/glycol mixtures with Glycol proportions > 40% to max. 50% by volume and one Media temperature from > + 40°C to max. +120°C or others Media other than water is an alternative Provide a mechanical seal. - Supply voltages: 3~480 V + -10% 50/60 Hz; 3~440 V +- 10% 50/60 Hz; 3~400 V + -10% 50/60 Hz; 3~380 V - 5% +10% 50/60 Hz accessories: - consoles for foundation mounting - 0-10 V differential pressure sensor sets for pumps in this version ... -R1 - IR monitor - IR stick - IF module PLR - LON IF module - Modbus IF module - BACnet IF module - IF module CAN Standard equipment: - Green button hand control panel for: - pump on/off - Choice of control mode: Δp-C (differential pressure constant), Δp-V (variable differential pressure), PID control, n-constant (controller) - Setpoint or speed setting - Configuration of operating parameters - Error acknowledgement - Pump display to display: - Control type - Target value (e.g. differential pressure or speed) - Error and warning messages - Actual values (e.g. power consumption, actual sensor value) - Operating data (e.g. operating hours, energy consumption) - Status data (e.g. status of the SSM and SBM relay) - Device data (e.g. pump name) - Operating mode (only for downpipe use: main /standby mode, parallel operation) Additional Features: - Analog interfaces 0-10 V, 2-10 V, 0-20 mA, 4-20 mA, integrated double pump management for use in Down pipe, two configurable alarm relays for operating and Fault messages, configurable error behavior tailored to heating and air-conditioning applications, pump access lock, integrated full motor protection (KLF) with electronic trigger, standard condensate drain holes in the motor housing (with delivery sealed), IR interface for wireless communication with the Wilo-IR Monitor control and service device and Wilo-IR stick, slot for Wilo IF modules Modbus, BACnet, CAN, PLR, LON for connection to building automation. Operational data Delivery medium: water 100% Media temperature: 20.00 °C Requested flow rate: 69.00 m³/h Requested delivery height: 6.00 m Media temperature: -20... 140 °C Ambient temperature: 0... 40 °C Maximum operating pressure: 16 bar Design note: 16 bar to 120 °C, 13 bar to 140 °C Minimum efficiency index (MEI): ≥ 0.7 propulsion Power supply: 3~400V/50 Hz Motor efficiency class: IE5 power consumption: 2520 W Rated motor power: 2,3 kW Current (max): 4.7 A Max. speed: 2200 rpm Interference emission: EN 61800-3 Immunity to interference: EN 61800-3 Insulation class: F Motor protection class: IP55 Motor protection: KLF integrated materials Pump housing: 5.1301, EN-GJL-250 KTL coated Impeller: PPS-GF40 Wave: 1.4542 Shaft seal: AQ1EGG Lantern: 5.1301, EN-GJL-250 KTL coated Installation dimensions Suction side pipe connection: DN 100, PN 16 Pressure-side pipe connection: DN 80, PN 16 |
Please Contact Us to Order to offer competitive prices and delivery time for Wilo - 2189123 Dry rotor block pump WITH frequency converter number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in Ireland Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
PUMP POWER: 3.0KW MAX PRESSURE: 16BAR FLOW CAPACITY: 217 L/MIN SERIAL NO. 01200006 VERTICAL MULTI STAGE PUMP MOTOR MODEL: PMI - 3004Q1 TYPE: TEFC POWER: 3.0KW VOLTAGE: 400 CURRENT: 6.2A RPM: 2886 FREQUENCY: 50 HZ
High pressure centrifugal pump Item number: 4077526
pump
PUMP SANTRIFUJ AS304
S 40/60 OIL PN 6. NR: 1274291/9610 - obsolete - REPLACED BY IPL 40/110-0,12/4 PN 16 -S2-440V-60Hz
complete pump440 volts, 55 IP, 50/60
for MTU 396
S40/60 OIL”, PN6, 115V60HZ, 2900RPM, 16UF, 170VDB.
Nv : 1274291-0109 3 phase 50/60 2500/2900rpm
MOTOR
STANDARDPUMPE WILO HISTORIC TOP-S 40/4 3~ PN 6/10-OIL ENERGIEEFFIZIENZKLASSE, ARTIKELNUMMER : 207208
Historic Wilo-TOP-S 40/4 3 ~ PN 6 / 10th Oil Wet rotor drehzahlumschaltbar
Rotary vane vacuum pump
submersible dirty water pump
3 phase 400V water pump
Glandless standard pump Item number: 2059857
TWI 6.1817-B 9,3 KW + SMR6-930T (DOL) 9,3 KW
MOTORLESS Bare Pump + 6 'foldable ELECTRIC MOTORS
WILO-HISTORIC TOP-S 40/4 3~ PN 6/10-OIL, NASSLÄUFERPUMPE DREHZAHLUMSCHALTBAR, ARTIKELNUMMER : 207208
Historic Wilo TOP-S 40/4 3 ~ PN 6 / 10th Oil Energy efficiency class: - Can be used for hot water heating systems, Air conditioning, closed cooling circuits and industrial Circulation systems. Maintenance-free glandless circulation pump Threaded or flanged, selectable Speed stages for power adjustment.
Wilo-Economy MHI 405N 3~400/1.4404/Viton PN10
System: high pressure centrifugal pump Wilo-Economy MHI 405N 3 ~ 400 / 1.4404 / Viton PN10 Pump housing: 1.4404 Shaft: 1.4404 Impeller: 1.4404 Mechanical seal B-carbon / ceramic Stage chambers: 1.4404 Sealing: Viton Lid: 1.4404 Medium: water temperature (-15 ... + 110 ° C): 20 ° C Capacity: 0.00 m³ / h Head: 0.00 m (Max. 10 bar) operating pressure (Max. 6 bar) inlet pressure Engine: -Nennleistung P2: 1.1 kW -Nenndrehzahl 2900 1 / min -Stromart: 3 ~ 400V / 50Hz -Nennstrom: 2.7 A IP 54 Suction / Pressure connection: Rp 1¼ / Rp 1 Make: Wilo
Wilo-Economy MHI 805N 3~400/1.4404/Viton PN10
System: high pressure centrifugal pump Wilo-Economy MHI 805N 3 ~ 400 / 1.4404 / Viton PN10 Pump housing: 1.4404 Shaft: 1.4404 Impeller: 1.4404 Mechanical seal B-carbon / ceramic Stage chambers: 1.4404 Sealing: Viton Lid: 1.4404 Medium: water temperature (-15 ... + 110 ° C): 20 ° C Capacity: 0.00 m³ / h Head: 0.00 m (Max. 10 bar) operating pressure (Max. 6 bar) inlet pressure -Nennleistung P2: 2.2 kW -Nenndrehzahl 2900 1 / min -Stromart: 3 ~ 400V / 50Hz -Nennstrom: 5.1 A IP 54 Suction / Pressure connection: Rp 1½ / Rp 1¼ Make: Wilo
pump with connector fitting set 0.09 KW
18,5 KW
15kW
Trockenläufer-Standard-Einzelpumpe
Gleitringdichtung
S40/600 REPLACED BY IPL 40/110-0,12/4 PN 16 -S2
Pump for motor 127 42291/9605
IPL 40/110-0,12/4 PN 16 -S2- 440V 60Hz
Trockenläufer-Standard-Einzelpumpe